FRP-steel Double-wall tank Leak Detection Sensor
For FRP-Steel double-wall tanks, we install a SFLS-2DA/2C double-wall tank leak detection sensor into the lowest point of the interstitial space which is usually on the bottom of the tank. Any leak of the tank occurs, it will trigger an alarm. Usually, the leak of outer wall will lead water from the soil flow into the bottom of the interstitial space, and the leak of inner wall will lead fuel from the inside of the tank flow into the bottom of the interstitial space, then the liquid will be detected by the SFLS-2DA/2C double-wall tank leak detection sensor and trigger an alarm.

1.SFLS-2C Leak Detection Sensor

For FRP-Steel double-wall tanks, we install a SFLS-2C double-wall tank leak detection sensor into the lowest point of the interstitial space which is usually on the bottom of the tank. Any leak of the tank occurs, it will trigger an alarm. Usually, the leak of outer wall will lead water from the soil flow into the bottom of the interstitial space, and the leak of inner wall will lead fuel from the inside of the tank flow into the bottom of the interstitial space, then the liquid will be detected by the SFLS-2C double-wall tank leak detection sensor and trigger an alarm.

SFLD-2D-2.jpg

Functions:

● Leakage alarm

● Short circuit alarm

● Open circuit alarm


Parameters:

● Temperature: -40℃~60℃(fuel); 0℃~60℃(no freezing water)

● Length of sensor cable: 5m

● Specifications:Length: 176.5mm; Diameter: 39mm

● Minimum alarm level: 4mm(fuel); 21mm(water)

● Sensor accuracy : ≤2mm

● Enclosure protection class: IP68

● Detection accuracy: 2mm

● Minimum fuel thickness on water: 1mm


2.SFLS-2DA Leak Detection Sensor(discriminating)

For FRP-Steel double-wall tanks, we install a SFLS-2DA double-wall tank leak detection sensor into the lowest point of the interstitial space which is usually on the bottom of the tank. Any leak of the tank occurs, it will trigger an alarm. Usually, the leak of outer wall will lead water from the soil flow into the bottom of the interstitial space, and the leak of inner wall will lead fuel from the inside of the tank flow into the bottom of the interstitial space, then the liquid will be detected by the SFLS-2DA  double-wall tank leak detection sensor and trigger an alarm.

SFLD-2D-2.jpg

Functions:

● Water alarm

● Fuel alarm

● Short circuit alarm

● Open circuit alarm

● Can detect the hydrocarbon on the water, and trigger fuel alarm


Parameters:

● Temperature: -40℃~60℃(fuel); 0℃~60℃(no freezing water)

● Length of sensor cable: 5m

● Specifications:Length: 176.5mm; Diameter: 39mm

● Minimum alarm level: 4mm(fuel); 21mm(water)

● Sensor accuracy : ≤2mm

● Enclosure protection class: IP68

● Detection accuracy: 2mm

● Minimum fuel thickness on water: 1mm